ä¸åœ‹è—¥å…¸2020年版二氧化碳ä¸å°ç¢³æ°«åŒ–åˆç‰©çš„å«é‡æœ‰è‘—åš´æ ¼çš„æŽ§åˆ¶æŒ‡æ¨™ã€‚
碳氫化åˆç‰©ç…§æ°£ç›¸è‰²èœæ³•(通則0521)測定供試å“氣體å–本å“,å³å¾—å°ç…§å“氣體å–甲烷å«é‡ç‚º0.0020%的氣體(以氮氣為稀釋劑)。色èœæ¢ä»¶ç”¨çŽ»ç’ƒçƒç‚ºå¡«æ–™çš„色èœæŸ±(4mm×0.8m,80ç›®);柱溫為110℃;進樣å£æº«åº¦ç‚º110℃;檢測器為ç«ç„°é›¢å化檢測器,溫度為120℃測定法精密é‡å–供試å“氣體與å°ç…§å“氣體,分別注入氣相色èœå„€,在凈化溫度為360℃時測得的峰é¢ç©ç‚ºç›¸æ‡‰(yÄ«ng)空白值;精密é‡å–供試å“氣體與å°ç…§å“氣體,分別注入氣相色èœå„€,測定峰é¢ç©,減去相應(yÄ«ng)空白值åŽçš„å³°é¢ç©ç‚ºæ ¡æ£å³°é¢ç©é™åº¦æŒ‰å¤–æ¨™æ³•ä»¥æ ¡æ£å³°é¢ç©è¨ˆç®—,å«ç¢³æ°«åŒ–åˆç‰©(以甲烷計)ä¸å¾—éŽ0.0020%。
浩瀚色èœï¼ˆå±±æ±ï¼‰æ‡‰(yÄ«ng)用技術(shù)開發(fÄ)有é™å…¬å¸ï¼Œèˆ‡æ™‚俱進,在王經(jÄ«ng)ç†çš„å¸¶é ˜(lÇng)ä¸‹ï¼Œæ ¹æ“š(jù)《ä¸è¯äººæ°‘共和國藥典2020第四部》ä¸äºŒæ°§åŒ–碳的è¦æ±‚,æˆåŠŸçš„ç ”åˆ¶ç”Ÿç”¢(chÇŽn)新一代HHO-III Purification device二氧化碳凈化è£ç½®ï¼Œåœ¨å®‰æ·å€«Agilent7820A,7890B,8860,8890,島津ShimadzuGC-2010,GC-2014ç‰æ°£ç›¸è‰²èœå„€ä¸Šå®‰è£æ¸¬è©¦ï¼Œçµ(jié)果滿æ„。æ¤æ¬¾ç”¢(chÇŽn)å“在制藥單ä½å®‰è£ä½¿ç”¨ï¼Œæ•ˆçŽ‡é«˜ï¼Œæ•ˆæžœæ»¿æ„。
å稱:藥典二氧化碳(CO2)凈化è£ç½®
型號:HHO-III Purification device
應(yÄ«ng)用:2020版ä¸åœ‹è—¥å…¸äºŒæ°§åŒ–碳ä¸ç¢³æ°«åŒ–åˆç‰©æ¸¬å®š 氣相色èœæ³•






China Pharmacopoeia 2020 edition carbon dioxide has strict control indicators for hydrocarbon content.
Hydrocarbons shall be determined by gas chromatography (general rule 0521), and the gas of the test sample shall be taken as this sample, that is, the reference gas shall be taken as the gas with methane content of 0.0020% (nitrogen as diluent). Chromatographic conditions: chromatographic column with glass ball as packing (4mm × 0.8m, 80 mesh); The column temperature is 110 ℃; The sample inlet temperature is 110 ℃; The detector is a flame ionization detector. The temperature is 120 ℃. The determination method accurately measures the test sample gas and the control sample gas and injects them into the gas chromatograph respectively. The peak area measured at the purification temperature of 360 ℃ is the corresponding blank value; Accurately measure the test sample gas and the control sample gas, inject them into the gas chromatograph respectively, and measure the peak area. The peak area after subtracting the corresponding blank value is the limit of the corrected peak area. The external standard method is used to calculate the corrected peak area, and the hydrocarbon content (calculated by methane) shall not exceed 0.0020%.
Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd., keeping pace with the times, under the leadership of Manager Wang, has successfully developed and produced a new generation of HHO-III Purification device carbon dioxide purification device according to the requirements of carbon dioxide in the Pharmacopoeia of the People's Republic of China 2020 Part IV, and installed and tested on Agilent 7820A, 7890B, 88608890, Shimadzu GC-2010, GC-2014 and other gas chromatographs with satisfactory results. This product has been installed and used in pharmaceutical companies with high efficiency and satisfactory effect, and is highly praised by users.
Name: Pharmacopoeia carbon dioxide (CO2) purification device
Model: HHO-III Purification device
Application: Determination of hydrocarbons in carbon dioxide in Chinese Pharmacopoeia 2020 by gas chromatography
滕州市浩瀚色èœå„€å™¨æŠ€è¡“(shù)æœå‹™(wù)有é™å…¬å¸
電話:0632-5667636
傳真:0632-5667636
手機:15562228838,13963221227
地å€ï¼šå±±æ±æ»•å·žå¸‚平行路(商務(wù)部和技術(shù)部)
郵箱:wangxiaoying9@126.com
QQ:1404939462
è¯(lián)系人:王經(jÄ«ng)ç†
網(wÇŽng)å€ï¼šm.digitalclassicsdvd.com