9的国产精选久久_亚洲国产日本综合aⅴ_2021年最新最全婷婷丁香_久久国产这里有精品

聯(lián)系我們

 

聯(lián)系我們

浩瀚色譜(山東)應(yīng)用技術(shù)開(kāi)發(fā)有限公司
電話:0632-5667636
傳真:0632-5667636
手機(jī):15562228838,13963221227

地址:山東滕州市平行路(商務(wù)部和技術(shù)部)
郵箱:wangxiaoying9@126.com
QQ:1404939462
聯(lián)系人:王經(jīng)理
網(wǎng)址:m.digitalclassicsdvd.com

GDX-101高分子小球應(yīng)用藥典2015四部0521
  • GDX-101高分子小球應(yīng)用藥典2015四部0521

  • 發(fā)布時(shí)間:2025-3-14 9:57:2
  • 產(chǎn)品簡(jiǎn)介:
    型號(hào):GDX-101填充柱
    規(guī)格:2m*3MM,60-80目
咨詢熱線:0632-5667636

應(yīng)用《中國(guó)藥典》2015年版四部通則0861殘留溶劑測(cè)定法對(duì)藥品中的殘留溶劑進(jìn)行測(cè)定.方法 以頭孢硫脒的殘留溶劑檢測(cè)為例,探討了在使用固定的殘留溶劑檢測(cè)方法不能有效測(cè)定樣品中的殘留溶劑時(shí),如何應(yīng)用《中國(guó)藥典》2015年版四部通則0861的方法測(cè)定樣品中的殘留溶劑.結(jié)果 應(yīng)用《中國(guó)藥典》2015年版通則0861殘留溶劑測(cè)定法,對(duì)不同生產(chǎn)廠家的頭孢硫脒中的殘留溶劑進(jìn)行了全面準(zhǔn)確的測(cè)定.結(jié)論 在固定的殘留溶劑測(cè)定方法不能準(zhǔn)確測(cè)定藥品中的殘留溶劑時(shí),應(yīng)用《中國(guó)藥典》2015年版通則0861中的雙柱定性方法可以快速、準(zhǔn)確地鑒別出藥品中未知的殘留溶劑,針對(duì)待測(cè)樣品建立準(zhǔn)確的殘留溶劑測(cè)定方法.

?

編號(hào):20231124006
型號(hào):GDX-101填充柱
規(guī)格:2m*3MM,60-80目
使用溫度:250°C
應(yīng)用: yao典2025年版四部0521,0861,溶劑殘留測(cè)定
適用于:島津,安捷倫,賽默飛,瓦里安,布魯克,PE等

5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱5A分子篩填充柱

?

The determination of residual solvents in drugs was carried out using the 0861 residual solvent detection method in the 2015 edition of the Chinese Pharmacopoeia. Taking the detection of residual solvents in ceftriaxone as an example, this study explored the effectiveness of using fixed residual solvent detection methods when residual solvents in samples cannot be effectively determined, How to apply the method specified in the 2015 edition of the Chinese Pharmacopoeia to determine residual solvents in samples? Results: The residual solvent determination method specified in the 2015 edition of the Chinese Pharmacopoeia was applied to comprehensively and accurately determine residual solvents in cephalosporin from different manufacturers. Conclusion: When fixed residual solvent determination methods cannot accurately determine residual solvents in drugs, The dual column qualitative method in the 2015 edition of the Chinese Pharmacopoeia General Rule 0861 can quickly and accurately identify unknown residual solvents in drugs, and establish an accurate residual solvent determination method for the test sample

Number: 20231124006

Model: GDX-101 filled column

Specification: 2m * 3MM, 60-80 mesh

Operating temperature: 250 ° C

Application: Yao Dian 2025 Edition Part 4 05210861, Solvent Residue Determination

Applicable to: Shimadzu, Agilent, Thermo Fisher, Varian, Brooke, PE, etc

聯(lián)系人
手機(jī)號(hào)碼
電子郵件
驗(yàn)證碼
看不清楚?點(diǎn)擊換張圖片
我要評(píng)論:

(內(nèi)容最多500個(gè)漢字,1000個(gè)字符)

驗(yàn) 證 碼 :
提交信息