浩瀚色èœï¼ˆå±±æ±ï¼‰æ‡‰(yÄ«ng)用技術(shù)開發(fÄ)有é™å…¬å¸ï¼Œæ出了用HH-790CH4-GC便攜å¼ç”²çƒ·è½‰(zhuÇŽn)化çˆ-å應(yÄ«ng)ï¼æ°£ç›¸è‰²èœæ³•æ¸¬å®šå¾®é‡ï¼£ï¼¯å’Œï¼£ï¼¯ï¼’氣體的方法.試驗(yà n)了載氣æµé€Ÿã€å應(yÄ«ng)溫度和催化劑的è£ç½®ä½ç½®ç‰èˆ‡ï¼£ï¼¯å’Œï¼£ï¼¯ï¼’轉(zhuÇŽn)化為CH4的關(guÄn)系.得出了最佳æ¢ä»¶ï¼šè¼‰æ°£æµé€Ÿï¼”ï¼ï½žï¼–ï¼ï½ï¼¬ï¼ï½ï½‰ï½Žï¼›å應(yÄ«ng)溫度:分離溫度6ï¼â„ƒï¼Žä»¥æ¨™(biÄo)氣為åƒç…§ï¼Œæ¸¬å®šäº†æ°£é«”ä¸å¾®é‡ä¸€æ°§åŒ–碳,二氧化碳,ç²å¾—了滿æ„çš„çµ(jié)果.方法的相å°å差在±5%以下,æ¤æ³•ä¹Ÿé©ç”¨äºŽé‡‘屬ä¸å¾®é‡ç¢³çš„測定.
?
å稱:甲烷轉(zhuÇŽn)化çˆ
填料:鎳觸媒â€
è¦(guÄ«)æ ¼ï¼šHH-790CH4-GC
應(yÄ«ng)用:微é‡ä¸€æ°§åŒ–碳,二氧化碳轉(zhuÇŽn)化æˆç”²çƒ·
特點(diǎn);
-
ç„¡éœ€æ”¹é€ å„€å™¨ï¼Œç›´æŽ¥å°æŽ¥ï¼Œçœæ™‚(shÃ),çœåŠ›ï¼Œå¯¦(shÃ)ç¾(xià n)ä¸åŒè¦(guÄ«)æ ¼åž‹è™Ÿ(hà o)的儀器互è¯(lián)互通
-
å«é€²(jìn)樣è£ç½®ï¼Œè‰²èœæŸ±ç³»çµ±(tÇ’ng),溫控系統(tÇ’ng),å¯é¸æ“‡ä¸å¿ƒåˆ‡å‰²æŠ€è¡“(shù),ä¿è·(hù)催化劑,延長使用壽命。
-
å¯é€£æŽ¥å®‰æ·å€«6890/7890/7820/8860/8890;島津GC2010/2014/2030;賽默飛1310系列;瓦里安3400系列;PE,布é¯å…‹ï¼›ç£è«¾A90系列;北分瑞利3400系列;ç¦ç«‹9790系列;å·å„€ï¼Œå¤©ç‘žï¼Œå¤©ç¾Žï¼Œè¯æ„›ï¼Œç§‘曉,æ·å³¶ï¼Œ
4.é«”ç©å°ï¼Œæ–¹ä¾¿æ”œå¸¶ï¼Œå®‰è£ç°¡å–®ï¼šä¸€é€²(jìn),一出2個(gè)接å£
?




?
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. proposed a method for determining trace amounts of CO and CO2 gas using HH-790CH4-GC portable methane conversion furnace reaction gas chromatography. The relationship between carrier gas flow rate, reaction temperature, and catalyst device position and the conversion of CO and CO2 to CH4 was tested. The optimal conditions were obtained: carrier gas flow rate of 40-60mL/min; Reaction temperature: Separation temperature of 60 ℃. Using standard gas as a reference, trace amounts of carbon monoxide and carbon dioxide in the gas were determined, and satisfactory results were obtained. The relative deviation of the method is below ± 5%, and this method is also applicable to the determination of trace carbon in metals
Name: Methane Converter
Filler: Nickel Catalyst
Specification: HH-790CH4-GC
Application: Trace carbon monoxide, carbon dioxide converted to methane
characteristic;
No need to modify the instrument, direct docking, saving time and effort, realizing interconnection and intercommunication of instruments of different specifications and models
Equipped with an injection device, chromatographic column system, temperature control system, and optional central cutting technology to protect the catalyst and extend its service life.
Can connect to Agilent 6890/7890/7820/8860/8890; Shimadzu GC2010/2014/2030; Thermo Fisher 1310 series; Varian 3400 series; PE, Brooke; Panno A90 series; Northern Raleigh 3400 series; Fuli 9790 series; Chuan Yi, Tian Rui, Tian Mei, Hua Ai, Ke Xiao, Jie Dao,
4. Small size, easy to carry, simple installation: one in, one out 2 interfaces
滕州市浩瀚色èœå„€å™¨æŠ€è¡“(shù)æœå‹™(wù)有é™å…¬å¸
電話:0632-5667636
傳真:0632-5667636
手機(jī):15562228838,13963221227
地å€ï¼šå±±æ±æ»•å·žå¸‚平行路(商務(wù)部和技術(shù)部)
郵箱:wangxiaoying9@126.com
QQ:1404939462
è¯(lián)系人:王經(jÄ«ng)ç†
網(wÇŽng)å€ï¼šm.digitalclassicsdvd.com